Single Straight Coolant-Hole Rods

Straight Coolant-Hole Rods

Single Straight Coolant-Hole Rods

A cemented carbide rod blank with one axial coolant passage running along the rod length.

Product Overview

A cemented carbide rod blank with one axial coolant passage running along the rod length.

Configuration & Design Characteristics

For drill and other tool blanks designed around a single internal coolant passage. Hole position and diameter must match the final tool geometry.

For this configuration, the coolant-hole geometry is a functional part of the blank design. Confirm the hole count, hole diameter d, hole tolerance, hole center position, eccentricity es and TK where two holes are present. The cross-section must match the tool drawing.

Technical Specifications

The 2026 KENIN catalog provides the following specification fields for this product:

Blank D, D tolerance, L, coolant-hole diameter d, hole tolerance and eccentricity/offset es. Selected examples include D 2.2–16.2 mm; this is not the full listed range, with lengths of 300, 330, 360 or 415 mm depending on row; refer to the full table for exact combinations.

Do not transfer a dimension or tolerance from another product family. Where the catalog lists multiple configurations under the same nominal diameter, select the exact row matching the required hole, pitch, length or profile.

★ Standard stock · ● Made to order. These are catalog supply classifications, not live inventory. Confirm availability and lead time with your quotation. Original units and tolerance notation are retained.

Single Straight Coolant-Hole Rods — Single-hole dimensions · 2026 catalog
Blank DD tol.L (mm)Hole dd tol.Offset esStock
2.2+0.1~+0.33000.3±0.100.10★
3.2+0.1~+0.33000.4±0.100.10★
4.2+0.1~+0.33300.6±0.100.10★
5.2+0.1~+0.33300.8±0.100.15★
6.2+0.1~+0.3330/3601.0±0.150.15★
6.2+0.1~+0.3330/3601.3±0.150.15★
7.2+0.1~+0.3330/3601.0±0.150.15★
8.2+0.1~+0.4330/3601.0±0.150.15★
8.2+0.1~+0.4330/3601.3±0.150.15★
9.2+0.1~+0.4330/3602.0±0.200.15★
10.2+0.1~+0.4330/360/4151.5±0.150.15★
10.2+0.1~+0.4330/360/4152.0±0.200.15★
11.2+0.1~+0.4330/360/4152.0±0.200.15★
12.2+0.1~+0.4330/360/4152.0±0.200.15★
12.2+0.1~+0.4330/360/4153.0±0.200.15★
13.2+0.2~+0.5330/360/4152.0±0.200.15★
14.2+0.2~+0.5330/360/4152.0±0.200.20★
15.2+0.2~+0.5330/360/4152.0±0.200.20★
16.2+0.2~+0.6330/360/4152.0±0.200.20★
16.2+0.2~+0.6330/360/4153.0±0.200.20★
17.2+0.2~+0.6330/360/4153.0±0.200.20★
18.2+0.2~+0.6330/360/4153.0±0.200.20★
19.2+0.2~+0.6330/360/4153.0±0.200.20★
20.2+0.3~+0.8330/360/4152.0±0.200.20★
20.2+0.3~+0.8330/360/4153.0±0.200.20★
21.2+0.3~+0.8330/360/4153.0±0.200.20★
22.2+0.3~+0.8330/360/4153.0±0.200.20★
23.2+0.3~+0.8330/360/4153.0±0.200.20★
24.2+0.3~+0.8330/360/4153.0±0.200.20★
25.2+0.3~+0.8330/360/4153.0±0.200.20★
26.2+0.3~+0.83303.0±0.200.25★
27.2+0.3~+0.83303.0±0.200.25★
28.2+0.3~+0.83304.0±0.250.25★
29.2+0.3~+0.83304.0±0.250.25★
30.2+0.3~+0.83305.0±0.250.25★
31.2+0.3~+0.83305.0±0.250.25★
32.2+0.3~+0.83305.0±0.250.25★
Single Straight Coolant-Hole Rods — Length tolerance — single straight hole · 2026 catalog
Length L (mm)Tolerance (mm)
<150+0.5/+1.0
150≤L≤300+1.0/+2.0
>300+2.0/+5.0

Material Grade Selection

Select the grade for the intended tool, workpiece material and cutting operation. KENIN reviews grade suitability and availability for the requested rod geometry; grade names do not establish equivalence.

KENIN Carbide Grades

Typical Applications

For drill and other tool blanks designed around a single internal coolant passage. Hole position and diameter must match the final tool geometry.

This page describes the blank configuration, not a guaranteed finished-tool performance result. Final tool life and machining performance depend on tool geometry, coating, machine conditions, workpiece and cutting parameters.

Customization & Drawing Review

For requirements outside the listed catalog configuration, send a dimensioned drawing. Depending on the geometry and confirmed manufacturing scope, the review may cover:

  • Outside diameter and length.
  • Hole count, diameter, position and spacing.
  • Helix angle and pitch, where applicable.
  • Chamfer, taper, slot, groove or stepped profile.
  • Ground or unground supply condition.
  • Required tolerances and inspection method.

Non-standard requests are subject to technical review and manufacturing feasibility confirmation.

Information Required for Quotation

Provide D, L, hole diameter d, eccentricity, tolerances, grade/application and quantity.

Please also include:

  1. Quantity per size.
  2. Required delivery destination.
  3. Any drawing revision or inspection specification.

Also state the required supply condition, surface requirements, desired delivery date and inspection method or acceptance specification. Delivery and feasibility are confirmed with the quotation.

Related Resources

Frequently Asked Questions

What are single straight coolant-hole rods?
A cemented carbide rod blank with one axial coolant passage running along the rod length.
Which details define a single coolant passage?
Specify hole diameter and tolerance, hole position and eccentricity relative to the rod center. TK is not a single-hole dimension.
What should I include when ordering single straight coolant-hole rods?
Provide D, L, hole diameter d, eccentricity, tolerances, grade/application and quantity. Include supply condition, surface requirements and the desired delivery date.
Can the single straight coolant-hole rods configuration be customized?
Submit the selected catalog reference and a dimensioned drawing. Specify hole diameter and tolerance, hole position and eccentricity relative to the rod center. Feasibility, grade and finishing must be confirmed for your request.
Does the catalog confirm current availability of single straight coolant-hole rods?
The catalog describes this configuration, not live inventory. Confirm the selected size, quantity and delivery requirement in the quotation; retain any size-specific supply classification.

Request a Quote for Single Straight Coolant-Hole Rods

Send KENIN the product reference, dimensions, tolerance requirements, grade or application details and quantity. A dimensioned drawing helps the team review the exact configuration.

Request a Quote Send Your Drawing